On April 8, 1998, an explosion and fire at the Morton International plant in Paterson, New Jersey, injured nine employees. The incident was the consequence of a runaway chemical reaction during production of Automate Yellow 96 dye, which overpressurized a 2,000-gallon chemical reaction vessel and released flammable material that ignited. Morton International was the CSB's first major reactive chemical investigation.
The CSB investigation found that Morton had experienced prior deviations from normal operating conditions during Automate Yellow 96 production -- near-miss events that were not systematically investigated or reported. These deviations were predictors of the runaway reaction that ultimately occurred but were not recognized as warning signals. The facility also lacked adequate pressure relief capability for the reactive process, and the MSDS for the Yellow 96 product contained incorrect physical property data.
The CSB issued 15 recommendations covering Morton International's corporate reactive chemical sharing program, the Patterson plant's reactive hazard management and pressure relief systems, OSHA and EPA joint reactive chemical guidelines, and outreach to industry associations. The Morton investigation was a key driver of the CSB's subsequent landmark study, Improving Reactive Hazard Management, which examined reactive chemical incidents across US industry.
This incident traced to breakdowns across 4 PSM elements (PHA · PSI · SOP · INC). Each represents a documented gap that process safety documentation and consulting can close before a similar event occurs at your facility.